Heating (Hot Blocks)
- Capable of heating up to 400º C
- Hot blocks available to accommodate 15, 25, 50 and 100 ml digestion vials
- Vilas available in Teflon, Glass and Polypropylene material
- Customise hot block available to accept specific size and shape of digestion vessel
- Teflon® coated graphite block and housing to prevent contamination
- Anodised Aluminum Block for higher temperature applications
- Choice of All-plastic housing for extreme corrosion resistance
- Unparalleled Temperature homogeneity of 1.50 C across the block
Post Digestion Sample Work-up
Wash Panel | Dilution, sample transfer mixing | |
---|---|---|
Makeup Volume: Sample levels are monitored for individual vials using non contact level sensor. Peristaltic pump fills in quickly major amount for desired level. Accurate Syringe pump dispensing and level sensor monitoring is used in achieving final level. This unique combination of syringe and peristaltic pump helps speed up process with out losing accuracy.
Dilutions and Sample Transfer: With the help of Teflon coated Carbon Fibre probe and Sample loop samples are picked up, stored, diluted and transferred to autosampler racks. Sample Probe and Loop is thoroughly cleaned externally and internally between each sample processing. It is possible to generate multiple dilutions for one sample in one go.
Cooling: Pneumatically driven acid resistant Tray Lift brings samples out of hot blocks. Tray Lift is placement forces cool air to pass over the vials, bring them rapidly to room temperature for multiple reagent additions and Volume Make-up.
Stirring: Vigorous mixing of sample is effected through rapid stream of air bubbles. Duration of mixing for each sample can be set as per need.
Wash Station: Two Chambered wash station is used for cleaning the probes between two sample. Wash station has two separate peristaltic pumps circulating clean water for efficient cleaning.
Dispensing Reagents
- Accurate and consistent reagent delivery for acids and reagents through dedicated lines
- Capable of handling corrosive acids like HF, H2SO4 and HClO4
- Deliver reagents and acids as required by each sample in a single run, thus can handle multiple types of samples at one time
- Can configured to dispense reagents in multiple vials to increase the speed
Syringe Pump
|
|
Peristaltic Pump |
|
Diligent Software Control
- Easy-to-build digestion recipe with functional steps like reagent addition, heating, stirring, sample transfer, washing and autosampler rack preparation
- Offers unique functionalities like Heat to Dryness and Precipitate / Residue washing
- Easy-to-set automation functions resulting in quick optimisation of the whole process
- Capable of altering processing for individual vial in single run
- Allows running of different digestion recipes at same time on each block
- Easy-to-configure variety of hot block and sample rack configurations
- Accepts rush, urgent or stat samples during the run
- Accepts changes in processing parameters in the run
- Capable of continuing process after break
- Estimates and displays digestion process time and progress
- Prompts when reagent bottles need replacement
- Process documentation capability
All Plastic Housing
- Saves prime lab space with smart inbuilt fume hood
- Perchloric-acid-Ready, detachable exhaust manifold to facilitate washing
- No metal parts, all plastic construction suitable for trace level sample preparation
- Laminar flow exhaust path for acid fume removal
- Positive air pressure in electronic section prevents acid corrosion
- Option of HEPA filter attachment
- Provides catchment basin for any reagent spillage
- Has transparent window for light illumination and visual observation