| Flow rate generated | H2O 2SLM, TEOS 600 SCCM (Max.) | 
| Operating pressure | Max. 1.33kPa | 
| Source tank volume | 2.7L | 
| Heat regulation method | PID control by the heat regulator | 
| Liquid surface detection method | Floating switch | 
| Internal mass flow controller | SEC-8400 series | 
| Air pressure valve | Bellows type | 
| Materials in liquid connection and gas contact area | SUS316L, PFA | 
| Operating Temperature | 20 to 35°C | 
| External input | Air pressure valve open/close, mass flow controller flow rate setting signal (0 to 5 V DC/0 to 100% F.S.), emergency stop signal, auto zero signal (option) | 
| External output | Temperature alarm, liquid level H.H. alarm, liquid level signal (H, M, L), READY signal, mass flow controller flow rate output signal ((0 to 5 V DC/0 to 100% F.S.), thermoregulated bath internal fan stop alarm, valve voltage monitor (option) | 
| Power source | AC 100 V, single phase 50/60 Hz, 1.5 kVA | 
| Other | Auto-recharge system: Can be connected to LU series. | 
| * The flow rate control range varies with the type of liquid. | |
| * SCCM and SLM are symbols indicating gas flow rate (mL/min, L/min at 0°C, 101.3 kPa). | |